{"id":4064,"date":"2016-06-25T12:08:41","date_gmt":"2016-06-25T05:08:41","guid":{"rendered":"http:\/\/dm3creative.com\/test\/?post_type=product&#038;p=4064"},"modified":"2016-08-20T19:15:41","modified_gmt":"2016-08-20T12:15:41","slug":"fl114","status":"publish","type":"product","link":"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/","title":{"rendered":"Fluke 170"},"content":{"rendered":"<h3><strong>Setting the multimeter standard<\/strong><\/h3>\n<p>For professional technicians worldwide there is one preferred solution: the precision, reliability and ease of use they find in\u00a0<a href=\"http:\/\/www.fluke.com\/Fluke\/uken\/Digital-Multimeters\/Fluke-289.htm?PID=56061\">Fluke 170 Series True RMS digital multimeters<\/a>. This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems.<\/p>\n<p>Fluke 170 Series digital multimeters give you True RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 177 and 179 provide higher 0.09% basic accuracy, a digital display with analog bar graph and backlight. And the Fluke 179 delivers temperature measurements.<\/p>\n<p>Fluke 170 series multimeters are independently tested for safe use in\u00a0<a href=\"http:\/\/support.fluke.com\/find_it.asp?Document=2173075\">CAT IV 600V\/CAT III 1000V environments.<\/a><\/p>\n\r\n\t\t<div class=\"tabbed-content shortcode_tabgroup pos_normal\">\r\n\t\t\t\r\n\t\t\t<ul class=\"tabs\"><li class=\"tab active\"><a href=\"#panel6530054421\">Advantages<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel6530054422\">Specifications<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel6530054423\">Environmental Specifications<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel6530054424\">Safety Specifications<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel6530054425\">Mechanical &amp; General Specifications<\/a><\/li><\/ul><div class=\"panels\"><div class=\"panel active\" id=\"panel6530054421\"><p>The Fluke 170 Series includes the following models:<\/p>\n<ul>\n<li>Fluke 179 True RMS DMM with 80BK Temperature Probe<\/li>\n<li>Fluke 177 True RMS DMM<\/li>\n<li>Fluke 175 True RMS DMM<\/li>\n<li>True RMS voltage and current measurements<\/li>\n<li>0.09% basic accuracy (177, 179)<\/li>\n<li>6000 count resolution<\/li>\n<li>Digital display with analog bargraph and backlight (177, 179)<\/li>\n<li>Manual and automatic ranging<\/li>\n<li>Display Hold and Auto Hold<\/li>\n<li>Frequency and capacitance measurements<\/li>\n<li>Resistance, continuity and diode measurements<\/li>\n<li>Temperature measurements (179)<\/li>\n<li>Min-max-average recording<\/li>\n<li>Smoothing mode allows filtering of rapidly changing inputs<\/li>\n<li>Easy battery exchange without opening the case<\/li>\n<li>Closed case calibration through front panel<\/li>\n<li>Ergonomic case with integrated protective holster<\/li>\n<li>EN61010-1 CAT III 1000V \/ CAT IV 600V<\/li>\n<li>Measures twice as fast as other multimeters<\/li>\n<\/ul>\n<\/div>\n<div class=\"panel\" id=\"panel6530054422\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Voltage DC<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>175 &#8211; Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (0.15%+2)<\/td>\n<\/tr>\n<tr>\n<td><strong>177 &#8211; Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (0.09%+2)<\/td>\n<\/tr>\n<tr>\n<td><strong>179 &#8211; Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (0.09%+2)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.1 mV<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a01000 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Voltage AC<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (1.0%+3)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.1 mV<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a01000 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Current DC<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (1.0%+3)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.01 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a010 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Current AC<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (1.5%+3)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.01 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a010 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Resistance<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (0.9%+1)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.1 \u03a9<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a050 M\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Capacitance<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (1.2%+2)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a01 nF<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a010,000 \u00b5F<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Frequency<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (0.1%+1)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.01 Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum<\/strong><\/td>\n<td>\u00a0100 kHz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Temperature<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>179 &#8211; Accuracy*<\/strong><\/td>\n<td>\u00a0\u00b1 (1.0%+10)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max. Resolution<\/strong><\/td>\n<td>\u00a00.1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td>\u00a0-40\u00b0C\/400\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Note<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>*<\/strong><\/td>\n<td>\u00a0Accuracies are best accuracies for each function<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"panel\" id=\"panel6530054423\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Environmental Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Operating Temperature<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0-10\u00b0C to +50\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Storage Temperature<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0-30\u00b0C to +60\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Humidity (Without Condensation)<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a00% &#8211; 90% (0\u00b0C &#8211; 35\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a00% &#8211; 70% (35\u00b0C -50\u00b0C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"panel\" id=\"panel6530054424\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Safety Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Overvoltage category<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0EN 61010-1 to 1000 V CAT III.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a0EN 61010-1 to 600 V CAT IV.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Agency Approvals<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0UL, CSA, T\u00dcV listed and VDE Pending<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"panel\" id=\"panel6530054425\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Mechanical &amp; General Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Size<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a043 x 90 x 185 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Weight<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0420 g<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Warranty<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0Lifetime<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Battery Life<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Alkaline:<\/strong><\/td>\n<td>\u00a0~200 hours typical, without backlight<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Setting the multimeter standard For professional technicians worldwide there is one preferred solution: the precision, reliability and ease of use they find in\u00a0Fluke 170 Series True RMS digital multimeters. This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems. Fluke 170 Series [&hellip;]\n","protected":false},"featured_media":4065,"comment_status":"open","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>INDOMETER - Fluke 170<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"INDOMETER - Fluke 170\" \/>\n<meta property=\"og:description\" content=\"Setting the multimeter standard For professional technicians worldwide there is one preferred solution: the precision, reliability and ease of use they find in\u00a0Fluke 170 Series True RMS digital multimeters. This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems. Fluke 170 Series [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/\" \/>\n<meta property=\"og:site_name\" content=\"INDOMETER\" \/>\n<meta property=\"article:modified_time\" content=\"2016-08-20T12:15:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/Fluke_177_DMM_300dpi_72x100mm_L_NR-21113.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/\",\"name\":\"INDOMETER\",\"description\":\"1 STOP METERING SOLUTION\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/work.ozzigeno.com\/indometer\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/Fluke_177_DMM_300dpi_72x100mm_L_NR-21113.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/#webpage\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/\",\"name\":\"INDOMETER - Fluke 170\",\"isPartOf\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/#primaryimage\"},\"datePublished\":\"2016-06-25T05:08:41+00:00\",\"dateModified\":\"2016-08-20T12:15:41+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl114\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product\/4064"}],"collection":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/comments?post=4064"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media\/4065"}],"wp:attachment":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media?parent=4064"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}