{"id":4081,"date":"2016-06-25T16:07:22","date_gmt":"2016-06-25T09:07:22","guid":{"rendered":"http:\/\/dm3creative.com\/test\/?post_type=product&#038;p=4081"},"modified":"2016-07-19T15:33:00","modified_gmt":"2016-07-19T08:33:00","slug":"fl121","status":"publish","type":"product","link":"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/","title":{"rendered":"Fluke 719"},"content":{"rendered":"<h3><strong>Forget the Hassle of Hand Pumping<\/strong><\/h3>\n<p>Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips!<\/p>\n<p>Use the programmable pump limit settings to eliminate over-pressurization, and to set \u2018pump to\u2019 pressure values. The unique cleanout port design reduces pump failures, and makes the 719 easy to clean without repair. The compact, lightweight form, combined with one-handed calibration, makes this pressure calibrator the ideal tool for busy process professionals.<\/p>\n<p>Pressure calibration made easy, by a name you know and trust for all your process calibration<\/p>\n\r\n\t\t<div class=\"tabbed-content shortcode_tabgroup pos_normal\">\r\n\t\t\t\r\n\t\t\t<ul class=\"tabs\"><li class=\"tab active\"><a href=\"#panel13541916411\">Advantages<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel13541916412\">General Specifications<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel13541916413\">Specification<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel13541916414\">Pump specifications<\/a><\/li><\/ul><div class=\"panels\"><div class=\"panel active\" id=\"panel13541916411\"><p><strong>Key Features:<\/strong><\/p>\n<p><strong><\/strong><strong><\/strong><\/p>\n<ul>\n<li>Electric pump for one handed pressure calibration<\/li>\n<li>Best in class pressure measurement uncertainty of 0.025%<\/li>\n<li>Measure and source mA with best in class 0.015% accuracy<\/li>\n<li>Precision pressure adjust vernier for accurate pressure calibration<\/li>\n<li>Variable release rate bleed valve for easy pressure adjustment<\/li>\n<li>Ideal performance for high accuracy transmitter calibration<\/li>\n<li>30 PSI and 100 PSI pressure ranges<\/li>\n<li>Programmable pressure calibrator pump limit:\n<ul>\n<li>eliminates over-pressurization<\/li>\n<li>allows the user to program target pressures for pumping<\/li>\n<\/ul>\n<\/li>\n<li>Extended pressure measurement range with any of 29 700Pxx Pressure Modules<\/li>\n<li>Source mA with simultaneous pressure measurement to test valves and I\/Ps<\/li>\n<li>Simulate mA signals to troubleshoot 4-20 mA loops<\/li>\n<li>Test pressure switches with built in switch test function<\/li>\n<li>Power transmitters during test using 24 V loop supply with simultaneous mA measurement<\/li>\n<li>Pressure Calibrator includes proven cleanout ports reduce pump failures<\/li>\n<\/ul>\n<\/div>\n<div class=\"panel\" id=\"panel13541916412\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">General Specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Storage temperature<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0-30 \u00b0C to 60 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Operating temperature<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0-10 \u00b0C to 55 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Relative humidity<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a095 % (-10 \u00b0C to 30 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a075 % (30 \u00b0C to 40 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a045 % (40 \u00b0C to 50 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a035 % (50 \u00b0C to 55 \u00b0C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Shock<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a01 meter drop test<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Safety<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0CSA C22.2 No. 1010.1:1992<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>EMC<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0EN50082-1:1992 and EN55022:1994 Class B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Size (HxWxL)<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a060 mm x 87 mm x 210 mm<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a0(2.19 in x 3.41 in x 8.28 in)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Weight<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0912 g (2 lb)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Battery<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0Two 9 V alkaline batteries<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Battery life<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a012 hours with 12 mA into 500 \u03a9, 200 pump cycles to 100 psi, 500 pump cycles to 30 psi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Warranty<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0Three-years, one year for pump<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"panel\" id=\"panel13541916413\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Fluke-719 30G<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td>\u00a0-12 to 36 psi, -850 mbar to 2.4 bar<\/td>\n<\/tr>\n<tr>\n<td><strong>Resolution<\/strong><\/td>\n<td>\u00a00.001 psi, 0.1 mbar<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td>\u00a00.025 % range for 6 months<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a00.035 % of range for one (1) year<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Fluke-719 100G<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td>\u00a0-12 to 120 psi, -850 mbar to 8 bar<\/td>\n<\/tr>\n<tr>\n<td><strong>Resolution<\/strong><\/td>\n<td>\u00a00.01 psi, 1 mbar<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td>\u00a00.025 % range for 6 months<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a00.035 % of range for one (1) year<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>mA<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td>\u00a00 to 24 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Resolution<\/strong><\/td>\n<td>\u00a00.001 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td>\u00a0.015 % Rdg + 2 counts<\/td>\n<\/tr>\n<tr>\n<td><strong>Notes<\/strong><\/td>\n<td>\u00a0Max load, 1000 \u03a9, 750 \u03a9 ohm in HART mode<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Loop supply<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><strong>Range<\/strong><\/td>\n<td>\u00a024 V dc<\/td>\n<\/tr>\n<tr>\n<td><strong>Resolution<\/strong><\/td>\n<td>\u00a0N\/A<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy<\/strong><\/td>\n<td>\u00a0\u00b1 10 %<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"panel\" id=\"panel13541916414\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Pump specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"150\"><strong>Maximum pressure generation<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0120 PSI (8 BAR) (100 PSI model)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Pump to<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a0&#8211; 30 PSI in less than 15 seconds*<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a0&#8211; 100 psi in less than 45 seconds*<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00a0*(with 1 meter of 1\/8 inch test hose)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Pump cycles between rebuilds<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a05000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\"><strong>Total pump life<\/strong><\/td>\n<td width=\"420\">\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u00a020,000 calibration cycle<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Forget the Hassle of Hand Pumping Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips! Use the programmable pump limit settings to eliminate over-pressurization, and to set \u2018pump to\u2019 [&hellip;]\n","protected":false},"featured_media":4082,"comment_status":"open","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>INDOMETER - Fluke 719<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"INDOMETER - Fluke 719\" \/>\n<meta property=\"og:description\" content=\"Forget the Hassle of Hand Pumping Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips! Use the programmable pump limit settings to eliminate over-pressurization, and to set \u2018pump to\u2019 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/\" \/>\n<meta property=\"og:site_name\" content=\"INDOMETER\" \/>\n<meta property=\"article:modified_time\" content=\"2016-07-19T08:33:00+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/719_Pro_300dpi_68x100mm_L_NR-15925.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/\",\"name\":\"INDOMETER\",\"description\":\"1 STOP METERING SOLUTION\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/work.ozzigeno.com\/indometer\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/719_Pro_300dpi_68x100mm_L_NR-15925.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/#webpage\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/\",\"name\":\"INDOMETER - Fluke 719\",\"isPartOf\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/#primaryimage\"},\"datePublished\":\"2016-06-25T09:07:22+00:00\",\"dateModified\":\"2016-07-19T08:33:00+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl121\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product\/4081"}],"collection":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/comments?post=4081"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media\/4082"}],"wp:attachment":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media?parent=4081"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}