{"id":4084,"date":"2016-06-25T16:41:35","date_gmt":"2016-06-25T09:41:35","guid":{"rendered":"http:\/\/dm3creative.com\/test\/?post_type=product&#038;p=4084"},"modified":"2016-08-20T19:14:30","modified_gmt":"2016-08-20T12:14:30","slug":"fl122","status":"publish","type":"product","link":"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/","title":{"rendered":"Fluke 721"},"content":{"rendered":"<p><strong>Pressure Calibration and Temperature Measurement for Custody Transfer Applications<\/strong><\/p>\n<p>The ideal tool for gas custody transfer applications is the Fluke 721 Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.<\/p>\n\r\n\t\t<div class=\"tabbed-content shortcode_tabgroup pos_normal\">\r\n\t\t\t\r\n\t\t\t<ul class=\"tabs\"><li class=\"tab active\"><a href=\"#panel2571854841\">Advantages<\/a><\/li>\n<li class=\"tab\"><a href=\"#panel2571854842\">Specification<\/a><\/li><\/ul><div class=\"panels\"><div class=\"panel active\" id=\"panel2571854841\"><p>The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).<\/p>\n<ul>\n<li>Ideal for gas flow calibration (custody transfer) applications<\/li>\n<li>Two isolated, stainless steel, pressure sensors with 0.025 % accuracy<\/li>\n<li>Pt100 RTD input for temperature measurement, (probe optional)<\/li>\n<li>Measures 4 to 20 mA signals<\/li>\n<li>Internal 24 V loop power supply can power a transmitter under test<\/li>\n<li>Measure up to 30 V dc, check 24 V loop power supplies<\/li>\n<li>Extend pressure measurement range with connection to external 700 series pressure modules (29 ranges)<\/li>\n<li>Large backlit graphic display can display up to three inputs simultaneously<\/li>\n<li>Store five instrument setups for recall and use<\/li>\n<\/ul>\n<\/div>\n<div class=\"panel\" id=\"panel2571854842\"><div class=\"datagrid\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"4\"><strong>Specifications 1-Year<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"180\"><strong>Fluke-721-1601<\/strong><\/td>\n<td width=\"179\"><strong>Range<\/strong><\/td>\n<td width=\"179\"><strong>Resolution<\/strong><\/td>\n<td width=\"179\"><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 psi to +100 psi,<br \/>\n-0.83 bar to 6.9 bar<\/td>\n<td>0.01 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-1603<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 psi to +300 psi,<br \/>\n-0.83 bar to 20 bar<\/td>\n<td>0.01 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-1605<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 psi to +500 psi,<br \/>\n-0.83 bar to 34.5 bar<\/td>\n<td>0.01 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-1610<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14\u00a0psi to +16 psi,<br \/>\n-0.97 bar to 1.1\u00a0bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0\u00a0psi to +1000 psi,<br \/>\n0.00 bar to\u00a069 bar<\/td>\n<td>0.1 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\"><strong>Fluke-721-1615<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +1500 psi,<br \/>\n0.00 bar to 103.4 bar<\/td>\n<td>0.1 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-1630<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +3000 psi,<br \/>\n0.00 bar to 200 bar<\/td>\n<td>0.1 psi,<br \/>\n0.01 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-1650<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +16 psi,<br \/>\n-0.97 bar to 1.1 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +5000 psi,<br \/>\n0.00 bar to 345 bar<\/td>\n<td>0.1 psi,<br \/>\n0.01 bar<\/td>\n<td>0.035% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\"><strong>Fluke-721-3601<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 to +100 psi,<br \/>\n-0.83 bar to 6.9 bar<\/td>\n<td>.01 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-3603<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 psi to +300 psi,<br \/>\n-0.83 bar to 20 bar<\/td>\n<td>0.01 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-3605<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-12 psi to +500 psi,<br \/>\n-0.83 bar to 34.5 bar<\/td>\n<td>0.01 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\"><strong>Fluke-721-3610<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +1000 psi,<br \/>\n0.00 bar to 69 bar<\/td>\n<td>0.1 psi,<br \/>\n0.001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-3615<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +1500 psi,<br \/>\n0.00 bar to 103.4 bar<\/td>\n<td>0.1 psi,<br \/>\n0.01 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-3630<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +3000 psi,<br \/>\n0.00 bar to 200 bar<\/td>\n<td>0.1 psi,<br \/>\n0.01 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Fluke-721-3650<\/strong><\/td>\n<td colspan=\"3\"><strong>Low pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>-14 psi to +36 psi,<br \/>\n-0.97 bar to 2.48 bar<\/td>\n<td>0.001 psi,<br \/>\n0.0001 bar<\/td>\n<td>0.025% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><strong>High pressure sensor<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0 psi to +5000 psi,<br \/>\n0.00 bar to 345 bar<\/td>\n<td>0.1 psi,<br \/>\n0.01 bar<\/td>\n<td>0.035% of full scale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><strong>General Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Instrument setup recall<\/strong><\/td>\n<td colspan=\"3\">Last used on power-up<\/td>\n<\/tr>\n<tr>\n<td><strong>Environmental<\/strong><\/td>\n<td colspan=\"3\">Operating temperature -10\u00b0C to +50\u00b0C<br \/>\nStorage temperature (without batteries) -20\u00b0C to +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Altitude<\/strong><\/td>\n<td colspan=\"3\">2,000 m<\/td>\n<\/tr>\n<tr>\n<td><strong>Ingress protection<\/strong><\/td>\n<td colspan=\"3\">IP-40<\/td>\n<\/tr>\n<tr>\n<td><strong>Power requirements<\/strong><\/td>\n<td colspan=\"3\">6.0 V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Battery life<\/strong><\/td>\n<td colspan=\"3\">&gt;35 hours, typical usage<\/td>\n<\/tr>\n<tr>\n<td><strong>Batteries required<\/strong><\/td>\n<td colspan=\"3\">(4) Standard AA cells<\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions (H x W x D)<\/strong><\/td>\n<td colspan=\"3\">7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm)<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td colspan=\"3\">03539 kg (1 lb 3 oz)<\/td>\n<\/tr>\n<tr>\n<td><strong>Connectors\/ports pressure<\/strong><\/td>\n<td colspan=\"3\">Two, 1\/8 in NPT, 700P Series Pressure Module; RTD Probe<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><strong>Electrical and Temperature Measurement 1-Year<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Function<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>mA measure<\/strong><\/td>\n<td>0 to 24 mA<\/td>\n<td>0.001 mA<\/td>\n<td>\u00b10.015% of rdg<br \/>\n\u00b10.002mA<\/td>\n<\/tr>\n<tr>\n<td><strong>V DC measure<\/strong><\/td>\n<td>0 to 30 V DC<\/td>\n<td>0.001 V<\/td>\n<td>\u00b10.015% of rdg<br \/>\n\u00b10.002 V<\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature measure (RTD\/ Ohms)<\/strong><strong>\u00b9<\/strong><\/td>\n<td>-40\u00b0C to 150\u00b0C<br \/>\n(-40\u00b0F to 302\u00b0F)<\/td>\n<td>0.01\u00b0C, 0.01\u00b0F<\/td>\n<td>\u00b10.015% of rdg<br \/>\n\u00b10.02 ohms<br \/>\n\u00b10.1\u00b0C (\u00b10.2\u00b0F)<br \/>\n\u00b10.25\u00b0C (\u00b10.45\u00b0F) combined uncertainty when using 720 RTD probe accessory<\/td>\n<\/tr>\n<tr>\n<td><strong>Loop power supply<\/strong><\/td>\n<td>24 V<\/td>\n<td>N\/A<\/td>\n<td>24 mA @ 24 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\u00b9Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><strong>Temperature Effect<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">No effect on accuracy on all functions from 15\u00b0C to 35\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">Add \u00b10.002% F.S.\/\u00b0C for temps outside of 15\u00b0C to 35\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><strong>Available Pressure Engineering Units<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">psi, bar, mbar, kPa, kgcm2, cmH<sub>2<\/sub>O @ 4\u00b0C, cmH<sub>2<\/sub>O @ 20\u00b0C, mH<sub>2<\/sub>O @ 4\u00b0C, mH<sub>2<\/sub>O @ 20\u00b0C, inH<sub>2<\/sub>O @ 4\u00b0C, inH<sub>2<\/sub>O @ 20\u00b0C, inH<sub>2<\/sub>O @ 60\u00b0F, mmHg @ 0\u00b0C, inHg @ 0\u00b0C, ftH<sub>2<\/sub>O @ 4\u00b0C, ftH<sub>2<\/sub>O @ 20\u00b0C, ftH<sub>2<\/sub>O @ 60\u00b0F<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Pressure Calibration and Temperature Measurement for Custody Transfer Applications The ideal tool for gas custody transfer applications is the Fluke 721 Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.<\/p>\n","protected":false},"featured_media":4085,"comment_status":"open","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>INDOMETER - Fluke 721<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"INDOMETER - Fluke 721\" \/>\n<meta property=\"og:description\" content=\"Pressure Calibration and Temperature Measurement for Custody Transfer Applications The ideal tool for gas custody transfer applications is the Fluke 721 Precision Pressure Calibrator. With dual isolated pressure sensors, it allows you to take simultaneous static and differential pressure measurements with a single tool.\" \/>\n<meta property=\"og:url\" content=\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/\" \/>\n<meta property=\"og:site_name\" content=\"INDOMETER\" \/>\n<meta property=\"article:modified_time\" content=\"2016-08-20T12:14:30+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/721_300dpi_83x100mm_L_NR-15932.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/\",\"name\":\"INDOMETER\",\"description\":\"1 STOP METERING SOLUTION\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/work.ozzigeno.com\/indometer\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/wp-content\/uploads\/2016\/06\/721_300dpi_83x100mm_L_NR-15932.jpg\",\"width\":500,\"height\":500},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/#webpage\",\"url\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/\",\"name\":\"INDOMETER - Fluke 721\",\"isPartOf\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/#primaryimage\"},\"datePublished\":\"2016-06-25T09:41:35+00:00\",\"dateModified\":\"2016-08-20T12:14:30+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/work.ozzigeno.com\/indometer\/shop\/fl122\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product\/4084"}],"collection":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/comments?post=4084"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media\/4085"}],"wp:attachment":[{"href":"http:\/\/work.ozzigeno.com\/indometer\/wp-json\/wp\/v2\/media?parent=4084"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}